How it connects
The 4x timber beam rests directly in the open steel seat/cradle channel and is secured laterally against uplift and rotation using through-bolts, machine bolts, or structural screws (such as Simpson Strong-Drive SDS screws).
Male and female halves
Female open cradle / channel receiving a male rectangular wood beam.
Usually connects to
- Matching dimensional-lumber joist/beam, nominal 2x or 45–50 mm, including 2 × 4/6/8/10/12 and doubled members
- Matching nominal 4x beam, including 4 × 6/8/10/12
- Matching 3-1/2 in glulam or other structural timber beam
- Double 2x wood truss
Common sizes
- Hanger widths vary with lumber: 1-1/2 in (38.1 mm) for nominal 2 in lumber, 45/50 mm single joists and about 90 mm doubled joists.
- Other listed seats include 3-5/8 in (92 mm) clear width for 3-1/2 in (89 mm) lumber, or 3-1/8 in (79–80 mm) for two 1-1/2 in plies.
- Seat depths may be 1–2 in; larger seats are listed 7–11 in long, side flanges 4–7 in (100–175 mm), with overall heights up to 26 in. Match the exact member and hanger.
Where it is used
Residential/commercial timber framingDeck/post-and-beam structuresPergolas/architectural timberJoist protection/waterproofingFoundation blocks, floating decks and adjustable pedestalsShed/walkway substructures
Variations
- Column Cap Only (CCO / CCOQ); Welded column cap cradle
- Standard Column Cap with post straps (CC / CCQ); End Column Cap (ECC / ECCQ) with closed end
- splayed skirt profile for ease of insertion
- straight 90-degree U-channel friction-fit
- single joist (approx. 45-50 mm) and double joist profiles
- intersecting cross slot (supporting 2-way 2x joists or 4x4 posts)
- adjustable-width joist cradle
- Face-mount double 2x hanger; Top-flange double 2x hanger
How to recognise it
A heavy-gauge (often 3-gauge to 7-gauge) formed steel channel with open front and back ends, flat bearing base, vertical side flanges with pre-drilled bolt or structural screw holes, sized at ~3-5/8 in clear width.
Often confused with
| Confused with | How to tell them apart |
|---|---|
| nominal 4x post cap saddle | Post cap cradles are often inverted or have distinct downward post straps, while beam seats are open-ended at both ends to allow the beam to pass through. |
| closed-end beam hanger (face-mount or top-flange hanger) | A beam hanger has a closed back flange designed for terminating a beam at a ledger or girder, whereas an open cradle allows continuous passthrough. |
| Self-adhesive joist tape | Joist caps are rigid extruded or moulded plastic/metal profiles with formed downward skirts rather than flexible adhesive tape rolls. |
| Structural joist hanger | Joist hangers support joists from ledger boards/beams via metal flanges and nails; joist caps sit along the top bearing face for water runoff and locating. |
| Nominal 4x4 post pocket | 4x4 post pockets are square cavities (3-1/2 x 3-1/2 in) designed for vertical posts, whereas joist channels are open-ended slots 1-1/2 in wide. |
Also called
column cap beam cradle; column cap beam seat; column cap only (CCO / CCOQ) cradle4x beam channelU-bracket beam seatjoist cap saddle; joist cover saddle; 2 inch joist saddlejoist protector channel; deck block joist slot; deck block channel2x lumber cradlebeam bearing cradle2-ply 2x joist hanger seat
Good to know
Often found on structural connectors like Simpson Strong-Tie CCO / CCOQ / CC / CCQ series. The term describes the open-ended top channel port that houses the horizontal timber beam. Additional standard references: ICC-ES ESR-2553; ASTM D7147.
Related connections
Design with real parts