How it connects
The breaker hooks onto the mounting rail at its wire-terminal end, then rotates down so its spring jaw pushes onto the bus stab. Spring pressure on the stab holds contact. Nothing is threaded and there is no seal.
Male and female halves
The breaker's spring jaw is the female (receptacle) half. The load center's flat bus stab is the male (blade) half. This port is the female breaker jaw.
Usually connects to
- Matching bus stab/finger in a compatible Square D Homeline load center or combination service-entrance device
- Homeline mounting rail at the breaker’s opposite end
Common sizes
- Homeline is described as 1 in (25.4 mm) per pole, with 1-, 2- and 3-pole versions; a conflicting 3/4 in (19 mm) description also appears. Confirm the panel family before selecting a breaker.
- Ratings span roughly 10–150 A at 120/240 V, with many branch ranges ending at 125 A.
- HOMT tandems put two circuits in one space and require notched connectors. QO uses 3/4 in spaces; other families are not interchangeable except specifically UL-classified replacements.
Where it is used
Residential/light-commercial power distributionHomeline load centers/panelboardsCombination service-entrance devices
Variations
- Standard Homeline single-/two-pole jaw
- Two-pole jaws on adjacent stabs
- HOMT tandem/twin jaw with rejection notch, requiring approved notched stabs and panel positions
- Plug-on-neutral version with separate neutral-rail clip
How to recognise it
Look at the back end of a 1 in wide Homeline (HOM/HOMT) breaker, opposite the wire terminal. There is a slotted metal spring jaw roughly 12 mm long with a 2–4 mm gap. The other end has a hook notch that grips the panel's mounting rail.
Often confused with
| Confused with | How to tell them apart |
|---|---|
| Square D QO plug-on connection | QO breakers are 3/4 in wide per pole and fit only QO bus stabs. Homeline breakers are 1 in wide and fit only Homeline stabs. The two are not interchangeable. QO breakers are 3/4-inch per pole with a visual trip flag; Homeline is 1-inch per pole and not interchangeable. |
| Bolt-on breaker connection (e.g. QOB/NQ) | Bolt-on breakers have a screw tab bolted to the bus instead of a spring jaw. Bolt-on breakers have a screw/tab bolted to the bus instead of spring jaws. |
| Plug-On Neutral clip | The PON clip is a separate connection to the neutral rail, not the line-bus jaw. |
| Eaton BR / Siemens / GE 1-inch plug-on breakers | Similar 1-inch format but different jaw/rail geometry; Homeline breakers are labeled HOM and listed only for Homeline panels. |
Also called
Homeline plug-on breaker jawHOM breaker bus connectionHomeline bus stab connectionbreaker line jawbus stab clipplug-in breaker stab connection; HOM breaker plug-on connectionHomeline breaker bus clipHomeline line-side plug-in contact
Good to know
Square D Homeline is proprietary. Other brands and Square D QO do not mate with it. HOMT tandem breakers require tandem-rated, notched stabs.