How it connects
Molded flexible thermoplastic or fiberglass spring-tab flaps flex to allow NM cable insertion through the knockout port, biting or pressing against the cable jacket to prevent retraction and secure the cable without external hardware.
Male and female halves
Female receptacle/entry port on the enclosure that receives and friction-clamps a male nonmetallic sheathed cable.
Usually connects to
- Compatible NM-B/Romex sheath, including grounded 14/2, 12/2 and 10/2 examples, within the box/clamp rating
- UF-B underground feeder cable where rated
- Larger SE/SEU cable where rated
- Flexible cord or AC/MC/FMC only on types rated for it
Common sizes
- Typical NM-B cable sizes: 14/2, 14/3, 12/2, 12/3, 10/2 and 10/3 AWG; single/dual-cable capacity depends on the clamp rating.
- Box-entry trade sizes include 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2 and 2 in; grip also depends on round or flat/oval cable shape.
- Box dimensions and separate knockout sizes do not establish cable capacity.
Where it is used
Residential/light-commercial NM branch wiringSwitch/outlet boxesCeiling-fan/fixture junction boxesElectrical panels and service-entrance cable entriesNonmetallic ceiling boxes
Variations
- Molded ribbed spring-tab/flap/V-clamp
- Screw saddle in plastic/fiberglass box
- Metal spring-clip insert in knockout
- Round or flat/oval cable profile
- Combination NM/AC/flex
- Duplex two-cable entry
- Old-/new-work integral clamp
- Single-screw strap clamp
How to recognise it
Recognized by flexible molded plastic flap tabs or spring tension fingers positioned directly behind the rear or side knockout openings inside a nonmetallic electrical box.
Often confused with
| Confused with | How to tell them apart |
|---|---|
| External NM cable connector | External connectors (e.g., Halex push-in or two-screw NM connectors) are separate fittings installed into a standard knockout hole, whereas integral clamps are molded directly into or factory-integrated inside the box. |
| Nonmetallic conduit knockout | Conduit knockouts are smooth open circular punch-outs meant for PVC conduit male adapters or fittings, lacking gripping clamp tabs. |
| Cord grip / liquid-tight strain relief connector | Cord grips use a domed nut compressing a rubber bushing (sealed); this uses an exposed saddle and two screws. |
| Squeeze (AC/flex) connector | Squeeze connectors are for armored cable/flex conduit and often have an insulated throat; the saddle shape and listed cable types differ, though combination types exist. |
| Electrical wire connector (wire nut, terminal) | Those join conductors electrically; this only grips the cable sheath. |
Also called
Built-in/integral NM cable clampInternal plastic-box cable entry clampSaddle/strap cable clampTwo-/twin-screw NM connectorNM/SE cable connector
Good to know
Under NEC 314.17(C) Exception, single-gang nonmetallic boxes without integral clamps permit cables to enter unsecured if stapled within 8 inches, whereas multi-gang boxes or boxes with integral clamps secure the cable directly at entry and require conductor volume fill deduction per NEC 314.16(B)(2).